Manuals, FAQ's, additional support and compatible sensors for each item can be found on the item's product details page. Click on the Search icon at the top of the page and enter the model number of your weather station. User manual instruction guides for La Crosse Technology devices. User manual instruction guide for La Crosse Technology devices.. Professional Remote Weather Station. Dimensions: 2. Setting for:. Alarm Type:. Absolute Air Pressure. Relative Air Pressure.

Relative Air Pressure Alarm. Indoor Temperature. Indoor Temperature Alarm. Outdoor Temperature. Outdoor Temperature Alarm. Indoor Humidity. Indoor Humidity Alarm. Previous Page. Next Page. Lacrosse ws professional weather station: quick start 2 pages. Lacrosse wstwc clock-weather channel: quick start 2 pages. Wind speed, wind direction, wind chill and dew point display 37 pages. De- signed for everyday use, the weather station will prove to be an asset of great Table of Contents value for your personal use in the home or office.

Please read this instruction manual thoroughly to fully understand the correct operation of your weather Page station and benefit from its unique features. The manufacturer and supplier will not be held functions for certain weather conditions as well as records of all minimum liable for damages due to failure to comply with this instruction manual or Page 3: Packaged Contents Packaged Contents Setting up Before setting up, carefully unpack the contents onto a table or flat surface and First, choose to use the adaptor included in this set or batteries for operation.

Page 4 Pull away the rain cover of the thermo-hygro sensor to reveal the three sockets for the wind sensor, rain sensor and the base station Setting up using batteries: Connect the attached cables of wind and rain sensors to the correspond- ing sockets of the thermo-hygro sensor by clicking them into place Open the battery cover of the thermo-hygro sensor located below the three sockets and insert 2 x AA, IEC LR6, 1.

Page 5: Operation Using Cable Connection Or Wireless Mhz Operation using cable connection or wireless MHz LCD Overview Cable Connection: The following illustration shows the full segments of the LCD for descrip- Using this method of operation will provide interference free transfer of the tion purposes only and will not appear like this during normal operation weather data from the sensors to the base station.

Page 6: Function Test Function test holes also at the back of the unit. It is important to check that the MHz if using wireless connection and the WWVB radio controlled time signal can be Once the weather station is powered up, perform a function test by checking received before permanently mounting any of the units.

Page 8: Function Description Do not remove batteries or unplug the AC adaptor of the base station other- Function Description of the Weather Station wise all sets of recorded weather history data for transferring to the PC will be lost for full details of PC use, please see PC user manual in the enclosed After setting up, the following data will be displayed in different sections on the Heavy Weather CD-ROM.

There are also two weather tendency indicators to show the air Use the DISPLAY key to toggle through the displays for other weather infor- pressure tendency either side of the weather icons. Page Operation Keys Operation keys ALARM key - In normal mode to enter the alarm programming mode - In alarm programming mode to select the following The base station has 8 keys for easy operation.

Page Alarm Programming Modes The first case is Rainfall Total, which has neither maximum nor minimum Press the SET key to enter the alarm minute time set mode the minutes records since it will show only the total rainfall. Page 14 Pressure high alarm and low alarm setting Storm warning alarm setting 1 Press the ALARM key to enter the normal time alarm Unlike the other weather alarms, the storm warning alarm is set by entering 2 Continue to press the ALARM key until you reach the pressure high alarm the main manual setting mode as follows: set mode 1 Press the SET key to enter the manual setting mode Page Auto-Memory For Stored Values When a set weather alarm condition has been activated, that particular alarm Auto memory for stored values will sound and flash for approximately 2 minutes but will continue to flash until weather conditions have become more steady.

The base station has a memory back up system, which is used to memorize user-defined settings for when the batteries are changed or if a power failure Weather Alarms occurs. Page Changing Batteries For best results, do not to add more than 32ft of extension cable from item to Problems and interference with operation item onto the existing cable lengths as this may reduce reception levels. Again, reception and interference levels will greatly depend on the surrounding environment at your point of mounting.

Page Transmission Range Transmission Range Specifications The transmission distance from the thermo-hygro sensor to the base station in Outdoor data open space under optimum conditions is ft. Although the signal transmis- Transmission Distance in Open Field ft max. Page Warranty Information La Crosse Technology, Ltd will repair or replace this product, at our option and at no Resolution charge as stipulated herein, with new or reconditioned parts or products if found to be Measuring Range Air Pressure 8.

This manual is also suitable for: Wsoak Wsch Wsmah. Print page 1 Print document 18 pages.